  Xcite 1100 Field Test Series

 

 

1100 Field Test Series

 

XCITE 1100 FIELD TEST SERIES

The Xcite 1100 Field Test Series uses the same Exciter Heads and Master Controller as the 1100 Laboratory Series but replaces the 5 GPM 3-Phase Hydraulic Power Supply with a field portable 1.2 GPM Single Phase Power Supply. While providing the same 3000 PSI pressure, the field test unit is switch selectable from 110 V (20 A) to 220 V (10 A) single phase power.

This simplified power requirement along with the packaging of the unit in a roto-molded shipping case provide for ease of modal testing in remote areas of your facility and allows air shipment to off site test destinations. The 1100Field Test Series is used in the power and natural gasdistribution industries as well as onshipboard structure borne noise path identification.

 

 

 

 

Xcite 1100-4-FT System
Xcite 1100-6-FT System
Xcite 1100-7-FT System
    1100-6 Field Test Manual Xcite 1100-7-FT Manual
Hydraulic Power Supply
Master Controller
Exciter Head
Static Force
Dynamic Force
Stroke
Rod
Bore
Thread
Load Cell
LVDT
Exciter Design
1001P 1.2 GPM (5 l/m)
1104-Mod4
1106-4-T/C
1,000 lb (4,450 N)
1,000 lb (4,450 N)
1.0 in (25 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
1.0 in (25 mm)
Single Ended
1001P 1.2 GPM (5 l/m)
1104-Mod4
1107-4-T/C
1,000 lb (4,450 N)
1,000 lb (4,450 N)
2.0 in (50 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
2.0 in (50 mm)
Single Ended
1001P 1.2 GPM (5 l/m)
1104-Mod4
1114-4-T/C
Total Static & Dynamic
Force = 1,000 lb (4,450 N)
1.0 in (25 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
1.0 in (25 mm)
Double Ended

 

1100 Field Test
1100 Field Test

 

Exciter Head
A
B
C
D
E
F
G
H
I
 
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in(dia)
mm(dia)
in(dia)
mm(dia)
1106-4-T/C
6.12
153
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1107-4-T/C
7.12
178
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1114-4-T/C
8.78
220
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7

 

Xcite 1100-4 Field Test System
1100-6-T/C Exciter Head
1100-4 Field Test Peak Dynamic Force
1100-4 Field Test Peak Displacement
Xcite 1100-6 Field Test System
1100-7-T/C Exciter Head
1100-6 Field Test Peak Dynamic Force
1100-6 Field Test Peak Displacement

Xcite 1100-7 Field Test System
1114-4-T/C Exciter Head

1100-7 Field Test Peak Dynamic Force

1100-7 Field Test Peak Displacement

Note: The above force curve is for the Xcite 1114 Head used in Tension/Compression mode with ZERO STATIC FORCE and the load cell rigidly connected to the structure for "PUSH/PULL" operation. In Compression mode only with 500 lbs of Static Force the curves are derated to a maximum of 400-500 lbs Peak Dynamic. (Depending on the structure stiffness of the test article).