Xcite 1100 Laboratory Series 1100-6 Laboratory Manual

 

 

1100 Laboratory Series

 

XCITE 1100 LABORATORY SERIES

The Xcite 1100 Laboratory Series is the most popular of the Xcite product line because of its large force capacity and broad frequency range compared to its extremely compact size. The 5 GPM 3-Phase hydraulic power supply used in the system provides a high level of low frequency displacement response for testing system subassemblies and non-linear structures such as suspensions and elastomeric dampers. The small piston area of the exciter and the high performance servovalve combine to provide excitation to over 1000 Hz allowing structure borne noise path evaluations.

The systems are used for applications ranging from machine tools to jet engine bearing studies. The small package allows fixturing in small spaces such as under vehicles and inside gearboxes and drive trains of earthmovers, trains and trucks. The compact package is especially well suited for engine mount structural tests in automobiles and jet engine mounting pod evaluations.

 

 

 

Xcite 1100-4 System
Xcite 1100-6 System
Xcite 1100-7 System
Hydraulic Power Supply
Master Controller
Exciter Head
Static Force
Dynamic Force
Stroke
Rod
Bore
Thread
Load Cell
LVDT
Exciter Design
1201B 5 GPM (20 l/m)
1104-Mod4
1106-4-T/C
1,000 lb (4,450 N)
1,000 lb (4,450 N)
1.0 in (25 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
1.0 in (25 mm)
Single Ended
1201B 5 GPM (20 l/m)
1104-Mod4
1107-4-T/C
1,000 lb (4,450 N)
1,000 lb (4,450 N)
2.0 in (50 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
2.0 in (50 mm)
Single Ended
1201B 5 GPM (20 l/m)
1104-Mod4
1114-4-T/C
Total Static & Dynamic
Force = 1,000 lb (4,450 N)
1.0 in (25 mm)
.75 in (18 mm)
1.0 in (25 mm)
.38 - 24
2,500 lb (11,125 N)
1.0 in (25 mm)
Double Ended

 

1100 Laboratory Series
1100 Laboratory Series

 

Exciter Head
A
B
C
D
E
F
G
H
I
 
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in(dia)
mm(dia)
in(dia)
mm(dia)
1106-4-T/C
6.12
153
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1107-4-T/C
7.12
178
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1114-4-T/C
8.78
220
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7

 

Xcite 1100-4 Laboratory System
1106-4-T/C Exciter Head
1100-4 Laboratory Dynamic Force
1100-4 Laboratory Peak Displacement
Xcite 1100-6 Laboratory System
1107-4-T/C Exciter Head
1100-6 Laboratory Peak Dynamic Force
1100-6 Laboratory Peak Displacement
Xcite 1100-7 Laboratory System
1114-4-T/C Exciter Head
1100-7 Laboratory Peak Dynamic Force

1100-7 Laboratory Peak Displacement

Note: The above force curve is for the Xcite 1114 Head used in Tension/Compression mode with ZERO STATIC FORCE and the load cell rigidly connected to the structure for "PUSH/PULL" operation. In Compression mode only with 500 lbs of Static Force the curves are derated to a maximum of 400-500 lbs Peak Dynamic. (Depending on the structure stiffness of the test article).