The Xcite line of standard force generation systems includes a broad range of built-in features, as well as all the electronic and hydraulic equipment options for complete application versatility. These Xcite system’s were the first to be totally engineered for high frequency mechanical impedance testing with minimal operational training required. The end user is assured ease of use with little knowledge of electrohydraulic systems due to the systems flexibility of operation in numerous applications. All Xcite systems consist of three basic components: The Exciter Head, Master Controller, and Hydraulic Power Supply.

 

HYDRAULIC POWER SUPPLY

The Hydraulic Power Supply furnishes the Exciter Head with its hydraulic pressure, flow and filtration requirements. Xcite Hydraulic Power Supplies present a unique approach to meeting the fluid power requirements of the exciter heads. Each unit is transportable and self-contained to permit use at virtually any test site, yet its low noise characteristics make it equally suited for laboratory use. Power supply control is located on the Master Controller for ease of use. All Xcite power supplies furnish 3000 psi of pressure and are available in models ranging from 1 GPM to 75 GPM.

 

Field Test Hydraulic Power Supply
Air Cooled Laboratory Hydraulic Power Supply
Air Cooled Laboratory Hydraulic Power Supply
Water Cooled Laboratory Hydraulic Power Supply
1001P Field Test
Hydraulic Power Supply
1201B Air Cooled Laboratory
Hydraulic Power Supply
1301B Laboratory
Hydraulic Power Supply
1302C Water Cooled Laboratory
Hydraulic Power Supply

 
UNIQUE FEATURES OF THE HYDRAULIC POWER SUPPLY
  • Transportability
  • Quiet operation
  • Pressure compensation and variable volume; provides energy consumption because it supplies only the flow demanded by the exciter head
  • Housed in rugged, wheeled cabinet
  • Low Maintenance
  • 3 micron filtration
  • Operation features: 3-phase power sequence
    indicator, temperature and filtration warning lights
  • Automatic shutdown on over-temperature & clogged filter
  • Polarized quick disconnects
  • Available in air or water cooled models
  • Available in 110V & 220V, 380V or 440V 3-phase models

 

HYDRAULIC POWER SUPPLY STATISTICS
  1001P Field Test Hydraulic Power Supply 1201B Laboratory Hydraulic Power Supply 1301B Laboratory Hydraulic Power Supply 1302C Water Cooled Hydraulic Power Supply
Flow 1.2 GPM (5 l/m) 5 GPM (20 l/m) 15 GPM (60 l/m) 15 GPM (60 l/m)
Pressure 3000 PSI (206 Bar) 3000 PSI (206 Bar) 3000 PSI (206 Bar) 3000 PSI (206 Bar)
Pump Type Constant Displacement Var. Vol/ Press. Comp. Var. Vol/ Press. Comp. Var. Vol/ Press. Comp.
Motor 3 HP 10 HP 30 HP 30 HP
Voltage 110/ 220 Switch Selectable 220/ 380/ 440 Specify 220/ 380/ 440 Specify 220/ 380/ 440 Specify
Current 20/ 10 Single Phase 30/ 17/ 15 A Three Phase 72/ 42/ 36 A Three Phase 72/ 42/ 36 A Three Phase
Reservoir Capacity 5 Gal (20 1) 15 Gal (60 1) 40 Gal (160 1) 40 Gal (160 1)
Reservoir Fill/ Empty Pump Yes No No No
Cooling Air/ Oil Air/ Oil Air/ Oil Water/ Oil
Water Requirement N/A N/A DNA 8 GPM/ 50 PSI
70 F max
Oil Filtration 5 Micron Absolute 5 Micron Absolute 5 Micron Absolute 5 Micron Absolute
Polarized Quick Disconnects Yes Yes Yes Yes
Max Ambient Temp 104 F (40 C) 104 F (40 C) 104 F (40 C) 104 F (40 C)
Cabinet Roto-molded Plastic Metal Metal No
Wheels No Yes Yes Yes
Shut Down on:
   Low Oil Yes Yes Yes Yes
   Over Temp Yes Yes Yes Yes
   Dirty Filter No No No No
Alarm Light on:
   Low Oil No Yes Yes Yes
   Over Temp No Yes Yes Yes
   Dirty Filter No Yes Yes Yes
   Incorrect Phase DNA Yes Yes Yes
Emergency Stop Yes Yes Yes Yes
Pressure Gage Yes Yes Yes Yes
Temperature Gage Yes Yes Yes Yes
Oil Level Gage Yes Yes Yes Yes
Oil Required Mobil DTE 24 or Equal Mobil DTE 24 or Equal Mobil DTE 24 or Equal Mobil DTE 24 or Equal
Dimensions:
   Width 30 in (750 mm) 30 in (750 mm) 62 in (1550 mm) 50 in (1250 mm)
   Length 30 in (750 mm) 37 in (950 mm) 44 in (1100 mm) 36 in (900 mm)
   Height 36 in (900 mm) 53 in (1350 mm) 62 in (1550 mm) 50 in (1250 mm)
Weight without Oil 265 lb (120 kg) 860 lb (390 kg) 2000 lb (909 kg) 1500 lb (682 kg)
20 Ft (3 m) Power Cord Yes Yes Yes Yes